The Dräger Interlock® XT is a breath-alcohol measuring instrument that can prevent a vehicle from being started if the driver’s breath alcohol concentration is higher than a prescribed limit. It meets worldwide device requirements, offers the greatest possible convenience for the user, and sets a new standard for alcohol interlocks. FOR USE WITH AN IGNITION INTERLOCK RESTRICTION ONLY.

 

Benefits

Prior to starting the engine, the Dräger Interlock XT requests a breath sample. If alcohol is detected above a prescribed limit, the immobilizer system prevents the motor from starting. Otherwise, the starter is activated for the driver to start the vehicle. The device will also prompt the driver to retest periodically while en route. The device will not disrupt the engine function once the engine has been started, but the event will be recorded.

The Dräger Interlock XT determines the breath alcohol concentration via an electro-chemical sensor system. The device is responsive to alcohol only.

To avoid long waiting periods, Dräger put emphasis on the Interlock XT being ready to use. Its functionality is as good at -40 °F or +185 °F as it is in normal conditions. The name affix “XT” stands for “eXtended Temperature”.

The device immediately detects any attempt to use auxiliaries, such as air pumps or filters to bypass the Dräger Interlock XT. It will prevent the motor from starting in such cases.

The data memory records more than 30,000 events and can be read via special PC software.

Images and Videos

Downloads

User Manual

Overview

LifeSafer Interlock

L250 LifeSafer Interlock

The L250 Ignition Interlock is our smallest handset with the most reliable technology. It’s designed to prevent you from being able to start your vehicle until you pass the alcohol test. This vehicle ignition interlock device has an easy blow pattern (deep inhale, blow and hum a consistent tone) and a simple screen.

At LifeSafer, we invest in our technology to make sure you get the most reliable devices at the lowest priceSome states might require a camera along with your device. We’ll help you navigate your options and choose one that will keep you in compliance.

Having an ignition interlock device (IID) can give you the freedom to get back out on the road again. These devices, which are also commonly known as car breathalyzers, are able to quickly test and detect any alcohol levels present in the driver’s breath.

Whether installed following a DUI or voluntarily added as a safety feature, this device won’t let your vehicle start if it detects a specific level of alcohol. If you’re sober, you’ll be good to go.

 

Benefits

An ignition interlock device (IID) is a small handheld car breathalyzer device and measures the amount of alcohol in the user’s breath. Installing one is a common requirement following a drunk driving offense (DUI, DWI, DUI, OWI, or OVI).

In simplest terms, an interlock device is an in-car breathalyzer that prevents a user from starting a vehicle until a breath alcohol test is taken. An ignition interlock device is a proper term for devices sometimes referred to as “in-car breathalyzer” or “car interlock” or “blow and go”. LifeSafer is the premier provider of all these systems at low cost in almost 2,000 convenient locations, one that is likely near you. Ready to install?

 

If the IID registers the breath test results (BAC or Blood Alcohol Concentration) over the pre-set limit, the vehicle will not start. If the driver’s breath test is below the pre-set limit, the vehicle will start. The interlock device needs to be serviced and calibrated at an authorized service center regularly. The length between these appointments is determined by state law but typically occurs every 30, 60, or 90 days. The LifeSafer device is the smallest and easiest to use on the market. Reserve your device today!

Our ignition interlock is the easiest to use on the market. All you have to do is gently blow into the device, get your reading, and start your vehicle. Some states require you to hum into the device. To learn more about your state requirements, it is best to speak with one of our state experts.

Ignition interlock devices must be installed by a certified ignition interlock technician. This is in accordance with state requirements and provides you peace of mind knowing that a trained professional is installing the device in your vehicle. Schedule your same day installation now.

To make your installation as smooth as possible, bring the following with you:
All your ignition interlock paperwork, including court documents and any notices or forms from your state licensing agency.
Photo driver’s license: The name on the driver’s license must match the name of the person installing the interlock device.
Vehicle registration card: If you are not the registered owner of the vehicle that will have the interlock device installed, make sure you have a notarized letter from the registered owner that allows for the installation.

Images and Videos

Downloads

User Manual

Install Checklist

EZ MONITORING

24 HOUR MONITORING DEVICES

  • Programable court restrictions
  • Inclusion and/or exclusion zones
  • Maps of zones are provided
  • Immediate notification of violations
  • Custom schedule & range settings
  • No phone line required
  • Location verified every minute
  • DIVERT Program approved
  • Color picture verification
  • Court-ordered test schedule
  • Alcohol specific
  • Immediate results
  • No monthly recalibration
  • Portable
  • No phone line required